Abstract:CT interpretation requires radiologists to review hundreds of volumetric slices per examination, making reporting time-consuming and highly expertise-dependent. Automated CT report generation offers a promising route to improving clinical efficiency, yet the field still lacks a generalizable CT report generation foundation model that supports multi-region reporting and remains robust across external real-world cohorts. Intrinsic inconsistencies in reporting style and diagnostic terminology across cohorts make naive joint training prone to noisy textual supervision, thereby limiting model generalizability. Here we present Astra, a generalizable CT report generation foundation model trained on 90,678 thoracoabdominal CT-report pairs (CTRgDB) with 353,671 abnormalities spanning eight organ systems. By harmonizing report style and further refining diagnostic consistency via reinforcement learning, Astra achieves style-consistent and diagnostically accurate report generation across diverse anatomical regions and institutions. Evaluating on CTRgDB and six external cohorts, Astra achieves state-of-the-art performance with a 44.1% average improvement in fine-grained diagnostic metrics (P<0.001). In real-world clinical workflows, Astra assistance accelerates chest report drafting by 29.6% and improves abdominal report completeness by 11.3% (P<0.001). Furthermore, Astra also demonstrates broad utility as a foundation for CT AI development, improving downstream diagnostic performance and scaling vision-language pretrain through high-quality report synthesis. Overall, Astra serves as a broadly accessible clinical assistant and a pivotal infrastructure for the next generation of AI-powered healthcare.
Abstract:Contrast-enhanced computed tomography (CECT) is pivotal for highlighting tissue perfusion and vascularity, yet its clinical ubiquity is impeded by the invasive nature of contrast agents and radiation risks. While virtual contrast enhancement (VCE) offers an alternative to synthesizing CECT from non-contrast CT (NCCT), existing methods struggle with anatomical heterogeneity and spatial misalignment, leading to inconsistent enhancement patterns and incorrect details. This paper introduces PHASOR, a volumetric diffusion framework for high-fidelity CT VCE. By treating CT volumes as coherent sequences, we leverage a video diffusion model to enhance structural coherence and volumetric accuracy. To ensure anatomy-phase consistent synthesis, we introduce two complementary modules. First, anatomy-routed mixture-of-experts (AR-MoE) anchors distinct enhancement patterns to anatomical semantics, with organ-specific memory to capture salient details. Second, intensity-phase aware representation alignment (IP-REPA) highlights intricate contrast signals while mitigating the impact of imperfect spatial alignment. Extensive experiments across three datasets demonstrate that PHASOR significantly outperforms state-of-the-art methods in both synthesis quality and enhancement accuracy.